עברית

Vulnerability Intelligence

CVE-2026-52723

Critical 9.1

Published
Last modified
NVD status
Deferred

Description

ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration performs VAU server certificate validation in app/vau/VAUProtokoll.py without anchoring the signed_vau_server_pub_keys and AUT_VAU_CertData certificate path to independent trusted material. A network-positioned attacker between the DiGA backend and the ePA system can intercept the VAU handshake, supply attacker-controlled certificate and key material, and satisfy the circular trust relationship. Because TLS certificate verification is also disabled in affected versions, no independent server-authentication layer prevents the attack. The attacker can impersonate the VAU server, control the negotiated session keys, and read or modify all encrypted VAU traffic. This issue is fixed in version 1.3.0.

References5

Metrics

CVSS 3.1
9.1 CRITICAL Score source: CNA CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
EPSS — exploit probability
0% percentile: 33 · as of 11 November 2026
CWE
CWE-295

Could this be exploited in your environment?

A patch closes the known hole. A penetration test shows what an attacker can still reach — with proof.