עברית

Vulnerability Intelligence

CVE-2026-40552

Medium 4.7

Published
Last modified
NVD status
Deferred

Description

Multiple BinSoft products are vulnerable to Remote Command Execution. An authorized user with access to the application and direct access to the backend database can achieve system command execution by uploading an attachment and modifying its storage path in the database to reference an attacker-controlled remote network resource. Alternatively, it is possible to use a previously uploaded file and change its reference. When the application processes the attachment, and a user tries to open it, the referenced resource is executed by the system. Critically, this vulnerability can be exploited by any unauthenticated attacker by chaining it with CVE-2026-40550 and CVE-2026-40551, which allows obtaining database access, and logging onto any account. The described issue affects all published versions. The vendor stated that this issue is a direct result of the architecture model in which the software is distributed, and that it will be mitigated with a corrected installation manual.

References2

Metrics

CVSS 4.0
4.7 MEDIUM Score source: CNA CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:P/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS — exploit probability
0% percentile: 21 · as of 13 November 2026
CWE
CWE-669

Could this be exploited in your environment?

A patch closes the known hole. A penetration test shows what an attacker can still reach — with proof.