עברית

Vulnerability Intelligence

CVE-2026-19003

High 7.8

Published
Last modified
NVD status
Analyzed

Description

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.

Affected products

mongodb: bi connector odbc driver

References1

Metrics

CVSS 3.1
7.8 HIGH Score source: CNA CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 4.0
8.4 HIGH Score source: CNA CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS — exploit probability
0% percentile: 12 · as of 12 November 2026
CWE
CWE-121

Could this be exploited in your environment?

A patch closes the known hole. A penetration test shows what an attacker can still reach — with proof.