עברית

Vulnerability Intelligence

CVE-2026-10122

High 8.8

Published
Last modified
NVD status
Deferred

Description

A vulnerability has been found in TRENDnet TEW-432BRP 3.10B20. This affects the function formSetProtocolFilter of the file /goform/formSetProtocolFilter. Such manipulation of the argument protocol_name leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. The vendor explains: "This product has been EOL for 15 years (since 2009). As the item has been EOL for such a long time, we are not able to replicate or fix any vulnerabilities." This vulnerability only affects products that are no longer supported by the maintainer.

References5

Metrics

CVSS 3.1
8.8 HIGH Score source: CNA CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 4.0
7.4 HIGH Score source: CNA CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS — exploit probability
0% percentile: 41 · as of 15 November 2026
CWE
CWE-119CWE-121

Could this be exploited in your environment?

A patch closes the known hole. A penetration test shows what an attacker can still reach — with proof.