תיאור (מקור, אנגלית)
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.
מוצרים מושפעים
siemens: sinamics g220 firmware; siemens: sinamics g220; siemens: sinamics s200 firmware; siemens: sinamics s200; siemens: sinamics s210 firmware; siemens: sinamics s210
קישורים1
- cert-portal.siemens.com/productcert/html/ssa-027652.html Vendor Advisory
מדדים
- CVSS 3.1
-
9.8
CRITICAL
מקור הציון: NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 4.0
-
6.9
MEDIUM
מקור הציון: CNA
CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - EPSS — סבירות ניצול
- 0% אחוזון 11 · נכון ל-8 בנובמבר 2026
- CWE
- CWE-269
האם אפשר לנצל את הפגיעות הזו אצלכם?
עדכון אבטחה סוגר את הפרצה הידועה. בדיקת חדירות מראה לאן תוקף עדיין יכול להגיע — עם הוכחה.